Blog

Home     Blog       Case Study-Iron and Manganese Removal(Sr…


Case Study-Iron and Manganese Removal(Sri Lanka)

Case Study: Manganese & Iron Removal for Rural Community Well Water (Sri Lanka)


Overview

Project Location: Rural community, Western Province, Sri Lanka Client: Local water treatment engineering contractor Water Source: Bore well groundwater Target: Drinking water supply for 280 residents Core problem: High manganese, iron plus trace hydrogen sulfide . Many local wells fail WHO drinking water limits for manganese.

WHO guideline: Manganese ≤0.05 mg/L, Iron ≤0.3 mg/L


Raw Water Quality (Before Treatment)

  • Fe: 2.7 mg/L
  • Mn: 1.18 mg/L
  • H₂S: 0.22 mg/L
  • pH:7.2
  • DO: 5.6 mg/L
  • Turbidity: 2.4 NTU

Client’s Original Pain Points

  1. They previously tested Birm media: Manganese broke through quickly, and Birm cannot handle hydrogen sulfide; once H₂S exists, Birm loses catalytic activity.
  2. Greensand Plus option was rejected: Requires continuous potassium permanganate dosing. The village lacks professional operators, chemical storage & regular dosing management is difficult.
  3. Manganese is harder to remove than iron. Even after iron is removed, manganese often leaks out and causes black stains on taps, laundry and downstream RO membranes.
  4. Budget constraint: Want to reduce the total media filling weight for the same filter tank, cut material cost.

Solution: ZIMR Catalytic Iron & Manganese Removal Filter Media

ZIMR is composite manganese oxide catalytic media supported on natural zeolite.

  • Filter tank: Single FRP vessel, 1054 tank
  • Design flow rate: 1.2 m³/h
  • EBCT (Empty Bed Contact Time): 10 min
  • ZIMR filling volume: 180 L
  • Bulk density: 1050 kg/m³, filling weight: 189 kg
  • Operation mode: Chemical-free regeneration, only water backwash
  • Backwash setting: Backwash flow to achieve 35% bed expansion, backwash duration:15 mins, backwash cycle: 24–36 hours

Effluent Water Quality Result (Stable after 7 days ripening)

  • Fe: 0.08 mg/L (<0.3 mg/L)
  • Mn: 0.032 mg/L (<0.05 mg/L WHO standard)
  • H₂S: Not detected
  • Turbidity: <0.5 NTU
  • Run monitoring period: 6 months, no manganese breakthrough, no chemical dosing required.

Key Benefits Verified On-site

  1. Manganese removal stability: The catalytic MnOx coating continuously oxidizes dissolved Mn²⁺. Even with fluctuating raw water manganese, effluent manganese stays within WHO limits.
  2. Multi-contaminant removal in one tank: Iron + manganese + hydrogen sulfide removed together, also partial removal of arsenic and lead. No need multi-stage filter.
  3. Low operation threshold: No permanganate, no chlorine dosing. Local villagers can operate only with backwash. Perfect for remote rural projects without trained technicians.
  4. Lower filling mass: Compared with Greensand Plus in same tank volume, ZIMR’s lower bulk density reduces media procurement cost.
  5. Protect downstream equipment: No manganese leakage, avoid black coating blocking RO membranes, shower filters and pipelines.

Client Feedback

The contractor chose ZIMR as the replacement for Birm and Greensand Plus for all their village well water projects. Manganese leakage issue which troubled them for years is fully solved.